The same joint, the same bolt, the same load cycling on and off. The only thing you are changing is how tight the bolt was done up. Drag upward to tighten, down to slacken; the arrow keys do the same. End is tightened to near proof load; Home is barely finger tight. Watch the orange bracket — it is everything the bolt feels. Sound is off until you turn it on.
Tightening a bolt stretches it and squeezes the parts it holds together. The bolt ends up pulling with some force and the members end up pushing back with exactly the same force, and nothing moves. That force is the preload, and the control here is nothing but the preload.
Now pull on the joint. The instinct is that the bolt takes what you apply, because the bolt is what is holding it together. It does not. Pulling the joint apart relieves the squeeze in the members at the same time as it stretches the bolt a little more, and the members are far stiffer than the bolt — a short fat column of steel against a long thin one. Most of what you apply is spent un-squeezing the members. The bolt takes only its share of the stiffness, which for this joint is about a sixth.
That lasts exactly as long as there is squeeze left to relieve. When the compression in the members reaches zero the joint opens, and from that moment the members are carrying nothing whatever and the bolt is carrying all of it. On the plot the line stops being nearly flat and becomes the diagonal — the bolt now feels every pound you apply, and more importantly it feels every pound you take away again.
Bolts almost never fail by being pulled apart once. They fail in fatigue, from the swing rather than the size, which is the orange bracket. Keep the joint shut and the swing is a sixth of the load; let it open and the swing is the whole of it, several times a second, for as long as the machine runs.
A broken bolt is usually a loose-joint problem, not a weak-bolt problem. Fitting a stronger bolt at the same torque raises the preload hardly at all — the grade changes what the bolt can survive, not how hard somebody pulled the spanner. If the joint was opening before, it opens now, and the stronger bolt fails in the same place for the same reason. The fix is more preload, a bigger bolt, or a stiffer joint.
Past the point where the joint stops opening, tightening further does nothing for fatigue. The bracket stops shrinking, exactly and completely, and the rest of the tightening goes into the bolt's mean stress and into margin against everything else — slip, loosening, a bigger load than the one designed for. Those are good reasons to keep tightening to a proper figure. Reducing what the bolt feels from the load is not one of them, past that point.
Stated plainly, because a piece whose value is trustworthiness should not overclaim. The first list is the part that would change how you read the result. The second is scope — true, worth saying, and not load-bearing.
Scope, for completeness. True of the model, and none of it changes the answer above.
The subject changes; the method does not. If you have a failure mode, a mechanism, or a
process that people keep getting wrong because the diagram cannot move, that is the shape
of problem this suits. You get one file, the checks that hold it honest, and the notes
explaining every decision including the ones that were reversed.
Commissions start at £4,000 and take three to four weeks from an agreed brief.